<ErrorNumber>22277</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: NOTE: Slipsheet sensors did not detect slipsheet beteen plates. Check media x sst
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Slipsheet sensor detected a plate ( in stead of a slipsheet ) on the
top of the lower plate during picking.  This is not an error if the
media sst is set correctly, it is however unusual and means that the
firmware will attempt to pick a slipsheet from the bottom of the plate
lifted by the pcups.  If however the media sst is not correct, that will
cause the ss sensor to not recognize a slipsheet when there is one,
which will then also give this warning.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is a warning only, but should serve as a heads up to a possible
subsequent error. Normally the slipsheet will fall to the lower plate
when a plate is lifted in the bay. In this case none was detected, if
the slipsheet did stick to the plate being lifted, then it will be removed
normally, however it is more likely that there was no slipsheet at all
which is a problem and the adjacent plate may have become scratched.
Please take care to place one slipsheet between stacks of plates as
they are loaded.
</text></DescriptionText>
<DescriptionText><text>
If this warning occurrs when there was infact a slipsheet there, please
call Creo Response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
see above.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/media_cal_sst.xml</LinkAddress><LinkTitle>NVS: media sst</LinkTitle></Link>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:02 2008 PST
</Updated>
<Links>
</Links>
</Error>